TPLP-60(245-270W)

TPLP-60(245-270W)

ELECTRICAL DATA

TPL245P-60

TPL250P-60  

TPL255P-60

TPL260P-60

TPL265P-60

TPL270P-60

Nominal power

Pm (Wp)

245

250

255

260

265

270

Open circuit voltage

Voc (V)

36.42

37.08

37.74

37.94

38.07

38.27

Short-circuit current

Isc (A)

8.97

8.99

9.01

9.06

9.37

9.48

Voltage at max power

Vmp (V)

30.93

31.46

31.74

32.28

32.63

32.87

Current at max power

Imp (A)

7.92

7.95

8.03

8.05

8.13

8.22

Module eficiency

(%)

15.06

15.37

15.67

15.98

16.29

16.60

Cells eficiency

(%)

16.95

17.29

17.64

17.99

18.33

18.68

System Voltage

(V)

1000

Temp. coeficient Voc

(%; °C)

-0.36

Temp. coeficient Isc

(%; °C)

0.06

Temp. coeficient Pm

(%; °C)

-0.36

Operating temp.

(°C)

-40 to +85

NOCT

(°C)

45±2

The electrical data apply to standard test conditions (STC): Irradiance of 1000 W/m2 with spectrum AM 1.5 and a cell temperature of 25°C.

 

TECHNICAL DATA

Junction box

3 bypass diodes, IP67

Wire cross section (Ø, mm2)

4.0

Cable lenght (mm)

900

Connector type

MC4/MC4 compatible

Dimensions (L x W x H, mm)

1640 x 992 x 35

Weight (kg)

18.5

Cell dimensions (mm)

156 x 156

No of cells / assembly

60 / 6 x 10

Type of cells

poly-crystalline

Hail resistance

Max. Ø 28 mm at 23 m/s

Wind load

2400Pa / 244kg / m²

Mechanical load

5400Pa / 550kg / m²