TPLP-60(245-270W)
ELECTRICAL DATA | TPL245P-60 | TPL250P-60 | TPL255P-60 | TPL260P-60 | TPL265P-60 | TPL270P-60 | |
Nominal power | Pm (Wp) | 245 | 250 | 255 | 260 | 265 | 270 |
Open circuit voltage | Voc (V) | 36.42 | 37.08 | 37.74 | 37.94 | 38.07 | 38.27 |
Short-circuit current | Isc (A) | 8.97 | 8.99 | 9.01 | 9.06 | 9.37 | 9.48 |
Voltage at max power | Vmp (V) | 30.93 | 31.46 | 31.74 | 32.28 | 32.63 | 32.87 |
Current at max power | Imp (A) | 7.92 | 7.95 | 8.03 | 8.05 | 8.13 | 8.22 |
Module eficiency | (%) | 15.06 | 15.37 | 15.67 | 15.98 | 16.29 | 16.60 |
Cells eficiency | (%) | 16.95 | 17.29 | 17.64 | 17.99 | 18.33 | 18.68 |
System Voltage | (V) | 1000 | |||||
Temp. coeficient Voc | (%; °C) | -0.36 | |||||
Temp. coeficient Isc | (%; °C) | 0.06 | |||||
Temp. coeficient Pm | (%; °C) | -0.36 | |||||
Operating temp. | (°C) | -40 to +85 | |||||
NOCT | (°C) | 45±2 |
The electrical data apply to standard test conditions (STC): Irradiance of 1000 W/m2 with spectrum AM 1.5 and a cell temperature of 25°C.
TECHNICAL DATA | ||||
Junction box | 3 bypass diodes, IP67 | |||
Wire cross section (Ø, mm2) | 4.0 | |||
Cable lenght (mm) | 900 | |||
Connector type | MC4/MC4 compatible | |||
Dimensions (L x W x H, mm) | 1640 x 992 x 35 | |||
Weight (kg) | 18.5 | |||
Cell dimensions (mm) | 156 x 156 | |||
No of cells / assembly | 60 / 6 x 10 | |||
Type of cells | poly-crystalline | |||
Hail resistance | Max. Ø 28 mm at 23 m/s | |||
Wind load | 2400Pa / 244kg / m² | |||
Mechanical load | 5400Pa / 550kg / m² | |||